DOWNLOAD APP NOTE:
Gator® Anti-VHH Biosensors for Quantitation and Off-Rate Screening of Camelid VHH

At Gator® Bio, we pride ourselves on delivering more than just cutting-edge technology. Our team is dedicated to providing responsive, world-class customer service tailored to your needs. With customizable solutions designed to fit your specific workflows and a commitment to your satisfaction, we ensure you have the tools and support to achieve your research goals with confidence.
Your breakthroughs are what drive progress, and we’re here to support you every step of the way. Biolayer Interferometry (BLI) provides fast, and reliable analysis to help you unlock deeper insights into biomolecular interactions. With fast, responsive support and customized biosensors to adapt to all your research needs, we empower you to move from discovery to impact—because your success is our priority.
At Gator® Bio, we pride ourselves on delivering more than just cutting-edge technology. Our team is dedicated to providing responsive, world-class customer service tailored to your needs. With customizable solutions designed to fit your specific workflows and a commitment to your satisfaction, we ensure you have the tools and support to achieve your research goals with confidence.
Request more info or schedule a personalized product demo today!
Don’t miss the chance to explore how Gator Bio can revolutionize your workflow.
BLI technology revolutionizes protein quantitation with its ability to provide fast, accurate, and label-free measurements. Researchers can precisely determine protein concentrations, even in complex or unpurified samples, without the need for extensive sample preparation. This streamlined process saves valuable time and ensures reliable results, making it ideal for applications in drug development, quality control, and bioprocessing.
Gator Bio's BLI instruments offer unparalleled precision and efficiency for quantitation applications.
To learn more about BLI and Quantitation, please visit our website.
BLI empowers researchers to study molecular interactions with real-time, label-free kinetics analysis. By delivering precise association and dissociation rate constants, as well as binding affinities, BLI simplifies the characterization of biomolecular interactions. Its high sensitivity and straightforward workflows allow scientists to gain a deeper understanding of binding mechanisms, critical for therapeutic development, screening, and basic research.
Gator BLI is compatible with a wide range of biomolecules for kinetic investigations: antibodies, nanobodies, small molecules, membrane proteins, AAV, nucleic acids, and more. BLI is a mainstay for the label-free measurement of biomolecular interactions.
To learn more about BLI and Kinetics, please visit our website.
Knowing the epitope of an antibody is crucial to understanding its biology and therapeutic potential. Running epitope binning analysis earlier in the drug discovery pipeline can save time and increase efficiency. BLI simplifies the complex process of epitope binning with its high-throughput and real-time analysis capabilities. Researchers can characterize antibody binding profiles, differentiate overlapping or unique epitopes, and identify binding competition with ease. This powerful tool accelerates antibody discovery and development, offering clear and actionable insights into epitope diversity and target interactions.
Gator BLI can handle crude supernatants to allow epitope binning at the earliest drug discovery phase. Intellectual property rights can be known earlier to make sure you stand out among competitors.
To learn more about BLI and Epitope Binning, please visit our website.
From material to surface to results, our precoated, ready-to-use biosensors offer improved sensitivity, reduced nonspecific binding and a higher capacity to expand the user’s applications. Robust enough to take on serum and plasma, our biosensors can handle a vast array of applications and samples — both crude and purified — and can be regenerated and reused to lower the cost per assay and to increase the walk-away time of any assay.
| Gator Probes | Function | Applications | Dynamic Range | Regenerable |
|
ProA |
IgG titer |
Q |
0.02-2000 μg/mL |
Yes |
|
ProG |
IgG titer |
Q |
0.02-2000 μg/mL |
Yes |
|
ProL |
Kappa light chain titer |
Q |
0.02-2000 μg/mL |
Yes |
|
SA |
Biotinylated and Avi-tagged molecules |
K/EP |
Protein dependent |
No |
|
SA XT |
Biotinylated proteins and large molecules |
K |
Protein dependent |
No |
|
Flex SA |
Reusable SA kit |
K |
Protein dependent |
Yes |
|
SMAP |
Measurement of small molecules, peptides |
K |
Protein dependent |
No |
|
HFC |
Human IgG |
Q/K/QKR/EP |
0.05-300 μg/mL |
Yes |
|
HFCII |
Advanced human IgG |
Q/K/QKR/EP |
0.3-6000 μg/mL |
Yes |
|
MFC |
Mouse IgG |
Q/K/QKR/EP |
0.02-6000 μg/mL |
Yes |
|
Anti-FAB |
F(ab), F(ab)2 |
Q/K/QKR/EP |
0.3-3000 μg/mL |
Yes |
|
APS |
Direct adsorption |
K |
Protein dependent |
No |
|
AR |
Amine coupling immobilization |
K/EP |
Protein dependent |
No |
|
His |
His-tagged proteins |
Q/K/QKR/EP |
Protein dependent |
Yes |
|
Ni-NTA |
His-tagged proteins through Ni-NTA |
Q/K/QKR/EP |
0.25-1000 μg/mL |
Yes |
|
Strep-Tactin XT |
Proteins with Twin-Strep-tag® |
Q/K |
Protein dependent |
Yes |
|
Anti-PEG |
PEGylated LNPs |
Q/K |
Analyte dependent |
No |
|
Anti-GST |
GST-tagged proteins |
Q/K |
Protein dependent |
No for Q |
|
AAVX |
Direct binding titer (AAV1-10) |
Q/K |
1x109-1x1013 vp/mL |
Yes |
|
AAV9 |
Direct binding titer (AAV9) |
Q/K |
3x109-1x1013 vp/mL |
No |
|
HS AAV |
High sensitivity titer (AAV1-8, 10) |
Q |
1x107-5x1010 vp/mL |
No |
|
HS AAV9 |
High sensitivity titer (AAV9) |
Q |
1x107-1x109 vp/mL |
No |
|
AAV Ratio |
Empty vs Full Ratio |
Ratio |
0-100% full |
No |
|
Adeno Quant |
Adenovirus titer |
Q |
1x109-1x1011 vp/mL |
No |
|
Anti-VHH |
Binding camelid nanobodies |
Q/K |
0.05-10 μg/mL |
Yes |
Q = Quantitation; K = Kinetics; EP = Epitope Binning
Don't see what you need? We can work with you to create a custom biosensor for your application.
For a complete list of Gator Probes and Consumables, please visit: https://shop.gatorbio.com/
Gator Bio's Biolayer Interferometry (BLI) solutions are redefining biomolecular analysis with precision, speed, and simplicity. Designed for real-time, label-free measurements, Gator Bio empowers researchers to tackle complex challenges in protein quantitation, kinetics, and epitope binning. With user-friendly workflows, robust sensitivity, and unparalleled versatility, Gator Bio’s technology delivers accurate, reliable data to accelerate discoveries and streamline research processes. Whether you're advancing drug development or exploring molecular mechanisms, Gator Bio provides the tools you need to achieve breakthrough results.